Noahcali-100 Auto Veterinary Chemical Analyzer

LOCMEDT Noahcali-100 Auto Veterinary Clinic Chemistry Analyzer is used for animal biochemistry, electrolyte, coagulation and inflammation tests that ensure precise and reliable results. Portable and smart design, based on micro-fluidic technology, Noahcali-100 consist of an analyzer and disposable reagent disks. 


The reagent discs contains pre-installed diluent in center, lyophilized reagent beads in cuvettes along the perimeter. The QR code on the center of disc contains the calibration and disc type expiry lot information. Fully automatic design, the users only need 3 steps to get the result.


Features of Analizador Veterinario

Compact Design

Small Size 17*26*35cm

Easy Workflow

3 easy steps to get results

Noahcali-100 Auto Veterinary Clinic Chemistry Analyzer

Fully Automatic

No need centrifuge & calibration, Internal quality control, dilution and mixing are performed automatically.

Noahcali-100 Auto Veterinary Clinic Chemistry Analyzer

High Efficiency

Only three drops of blood, delivery up to 23 accurate results for a single run, with a total of 40 parameters on eight panels.  

Noahcali-100 Auto Veterinary Clinic Chemistry Analyzer

Low Cost

No other consumable parts, zero maintenance

Noahcali-100 Auto Veterinary Clinic Chemistry Analyzer

Data Transmission

Connect to user's computer, store data on the management software

How to Use Noahcali-100 Auto Veterinary Clinic Chemistry Analyzer

01

Add 100μL Sample

Add 100μL Sample

02

Insert the Disc

Insert the Disc

03

Read the Results

Read the Results

Noahcali-100 Auto Veterinary Chemical Analyzer

LOCMEDT Veterinary Biochemistry Analyzer

Basic Information of Noahcali-100 Auto Veterinary Clinic Chemistry Analyzer

Analyzer TypePortable clinical biochemistry analyzer for veterinary use
Testing Time8-12 minutes to delivery up to 22 parameters results
Analysisbiochemistry, electrolyte, coagulation and inflammation, total 40 parameters
Sample typesSerum, plasma, whole blood
Sample volume90– 120 μL
Bar code identificationAutomatic bar code scan for reagents and samples
Measuring principle  Colorimetry (rate; end point)
Reaction temperature  37 ± 0.2 °C
Photometry9 wavelengths: 340, 405, 450, 505, 546, 600, 630, 700 and 800 nm
System interfaceAnalyzer to PC: USB 2.0 connectivity bi-directional
Power sourceAC 110/240 V, 50-60 Hz; 300 VA excluding PC/printer/monitor
Dimensions17 cm (W) x26 cm (D) x 35 cm (H)
Weight 4.5 kg


Application of Noahcali-100 Auto Veterinary Clinic Chemistry Analyzer

Animal Hospital

Animal Hospital

Farm

Farm

Horse Ranch

Horse Ranch

Research Laboratories

Research Laboratories

FAQ

  • Q1: What kind of tests does the Noahcali-100 veterinary chemistry analyzer can do?

    Noahcali-100 can do tbiochemistry, electrolyte, coagulation and inflammation analysis.So the users do not need separate instrument for biochemistry, electrolyte, coagulation or inflammation

    Q2: How many kinds of panels can be used in Noahcali-100 Animal blood test analyzer?

    Noahcali-100 blood test analyzer only accept LOCMEDT reagent panels, see details at Disposable Reagent Disc.

    Q3: Does Noahcali-100 vet use chemistry analyzer require calibration?

    No, the Noahcali-100 analyzer reagent panels are factory-calibrated. The calibration information encoded in the QR code on the center of the rotor. When inserting the rotor, the analyzer can read it automatically.


    Q4: What maintenance does Noahcali-100 blood test analyzer require?

    High quality parts used, no consumable accessories inside.The xenon lamps as light source with decades of lifespan. It only needs some cleaning, see details in operator’s manual.

    Q5: What types of samples can be used with Noahcali-100 Clinical Chemistry Analyzer?

    The sample should be lithium-heparin whole blood, lithium-heparin plasma, or serum. Do not use EDTA as an anti-coagulant.


  • Q6: What is the Noahcali-100 Veterinary Biochemistry Analyzer sample volume required?

    Usually 90-120μL for a test(about 3 drops), but for Critical Care Panel 13 only accept 120μL plasma.


    Q7: What is the shelf life of the Noahcali-100 Biochemistry analyzer reagent discs?

    The shelf life of the disc can be 18 months and the discs should be stored refrigerated at 2-8°C


    Q8: Can expired disc be used in the Noahcali-100 Vet Blood Chemistry Analyzer?

    No, the analyzer will cancel the run and display an Error Code message.


    Q9: Does the disc require warm-up time before using?

    No, the users can use the disc directly from the refrigerator


    Q10: How long can the Noahcali-100 biochemistry analyzer reagent disc be used after removing from the foil pouch?

    After opening the pouch, the discs should be used in 20 minutes.


Related Products

Contact Info

Tel.: +86 22 5860 1276

Mob.: +86 155 1086 2356

E-mail: [email protected]

WhatsApp: 8615510862356

Add.: Floor 4, Building B3, Huaming High-tech Industrial Zone, No.6 Huafeng Road, Dongli District, 300300, Tianjin, China

Follow Us

Clinical Chemistry Analyzer,Portable Biochemistry Analyzer,IVD Device,Medical Lab Equipment, POCT Medical Diagnostic Device, Veterinary Blood Analyzer,Vet Lab Instruments,Blood Chemistry Analyzer,Electrolyte Analyzer, Blood Gas Analyzer, Biochemistry Analyzer Reagent Rotor.

Copyright © Tianjin LOCMEDT Technologies Co., Ltd. All Rights Reserved | Sitemap

Contact