LOCMEDT® Noahcali-100 portable vet use chemistry analyzer fully automated for the animal health diagnostics offers high-quality results with only 100 μl of whole blood, serum or plasma. Noahcali-100 can analyze up to 22 parameters at the same time in a single run and read the results after just 12 minutes.
Associated disposable reagent discs containing lyophilized reagent beads and diluent, make the instrument be extremely easy to use. Only 3 steps-add the blood sample, insert the rotor, read the results in 12 minutes.
Features of LOCMEDT® Noahcali-100 Portable Vet Use Chemistry Analyzer
● Advantages: combining the advantages of wet analyzer and dry chemistry analyzer together-easy operation,
fast accurate reliable result, no cross contamination.
● Multi-combinations of testing parameters: can test up to 34 parameters, including biochemistry, electrolyte, blood gas items.
● Microfluidic technology: Patented technology used in the reagent disc, individual channel, no crossing contamination.
● Patented technology of sealed reagents:Lyophilized reagent inside and diluent are sealed in the disc, no need to add diluent.
● No maintenance:no calibration, no consumable accessories inside.
● Accurate and Reliable result: Providing fast and accurate result, offering maximum support for diagnosis and treatment.
How to Use LOCMEDT® Noahcali-100 Portable Vet Use Chemistry Analyzer
01
Add 100μL Sample
02
Insert the Disc
03
Read the Results
LOCMEDT Veterinary Biochemistry Analyzer
Basic Information of LOCMEDT® Noahcali-100 Portable Vet Use Chemistry Analyzer
Name | Noahcali-100 | Usage | veterinary clinical chemistry analyzer |
Type | Bench Top | Panels | biochemistry, blood gas, electrolyte items |
Sample Type | Anti-coagulation whole blood, serum, plasma | Display | 7 inch capacitive touch screen Multi-language |
Sample Volume | 90-120 μl | Data Capacity | Max 500, 000 results |
Testing Time | 8-12 mins/sample | Printer | Built-in thermal printer |
Working Condition | Temperature:10-32℃ Humidity: 30%-80% | Data Transmission | WIFI, LIS |
QC & Calibrate | Automatic and Real-time | Size | 256mm(L)*172mm(W)*350mm(H) |
Reaction temperature | 37±0.2℃ | Weight | 4.5KG |
Power source | AC110-240V, 50-60Hz | Power Rating | 120W |
Application of LOCMEDT® Noahcali-100 Portable Vet Use Chemistry Analyzer
Animal Hospital
Farm
Horse Ranch
Research Laboratories
FAQ
Q1: What kind of tests does the Noahcali-100 veterinary chemistry analyzer can do?
Noahcali-100 can do the vet blood biochemistry, blood gas,electrolyte analysis.So the users do not need separate instrument for electrolytes or blood gas.
Q2: How many kinds of panels can be used in Noahcali-100 Animal blood test analyzer?
Noahcali-100 blood test analyzer only accept LOCMEDT reagent panels, see details at Disposable Reagent Disc.
Q3: Does Noahcali-100 vet use chemistry analyzer require calibration?
No, the Noahcali-100 analyzer reagent panels are factory-calibrated. The calibration information encoded in the QR code on the center of the rotor. When inserting the rotor, the analyzer can read it automatically.
Q4: What maintenance does Noahcali-100 blood test analyzer require?
High quality parts used, no consumable accessories inside.The xenon lamps as light source with decades of lifespan. It only needs some cleaning, see details in operator’s manual.
Q5: What types of samples can be used with Noahcali-100 Clinical Chemistry Analyzer?
The sample should be lithium-heparin whole blood, lithium-heparin plasma, or serum. Do not use EDTA as an anti-coagulant.
Q6: What is the Noahcali-100 Veterinary Biochemistry Analyzer sample volume required?
Usually 90-120μL for a test(about 3 drops), but for Critical Care Panel 13 only accept 120μL plasma.
Q7: What is the shelf life of the Noahcali-100 Biochemistry analyzer reagent discs?
The shelf life of the disc can be 18 months and the discs should be stored refrigerated at 2-8°C
Q8: Can expired disc be used in the Noahcali-100 Vet Blood Chemistry Analyzer?
No, the analyzer will cancel the run and display an Error Code message.
Q9: Does the disc require warm-up time before using?
No, the users can use the disc directly from the refrigerator
Q10: How long can the Noahcali-100 biochemistry analyzer reagent disc be used after removing from the foil pouch?
After opening the pouch, the discs should be used in 20 minutes.
Related Products
Navigation
Tel.: +86 22 5860 1276
Mob.: +86 155 1086 2356
E-mail: [email protected]
WhatsApp: +86 155 1086 2356
Add.: Floor 4, Building B3, Huaming High-tech Industrial Zone, No.6 Huafeng Road, Dongli District, 300300, Tianjin, China
Contact